Skip to content

Repository files navigation

OpenModScan Mobile

Flutter CI Release License: MIT

Mobile version of the OpenModScan Modbus master/client utility.

Screenshots

Devices screen, light theme Devices screen, dark theme Registers screen, light theme

Features

  • Save Modbus devices and register lists.
  • Connect to Modbus TCP and Modbus RTU/IP devices.
  • Read holding registers, input registers, coils, and discrete inputs.
  • Write holding registers and coils when writes are enabled.
  • Discover Modbus TCP and Modbus RTU/IP devices on the local network.
  • Inspect captured Modbus traffic with decoded frame details.
  • Export and import app settings and saved devices as a JSON backup.
  • Supports English and Russian UI localization.

Protocol Support

Protocol Notes
Modbus TCP Standard Modbus master/client connections over TCP.
Modbus RTU/IP RTU-style Modbus frames transported over TCP/IP.

Getting Started

Install Flutter (Dart SDK ^3.12.0), then fetch dependencies:

flutter pub get

Run the app:

flutter run

Build release artifacts for a target platform:

Android Android APK:

flutter build apk

Apple iOS:

flutter build ios

Note

iOS builds require Xcode and a configured Apple signing environment.

Quality Checks

Run static analysis:

flutter analyze

Run tests:

flutter test

Run tests with coverage:

flutter test --coverage

The CI workflow enforces at least 80% line coverage from coverage/lcov.info. Coverage output is a local artifact and is ignored by git.

Run integration tests (requires a connected device or running emulator):

macOS / Linux:

scripts/integration_test.sh

Windows (PowerShell):

.\scripts\integration_test.ps1

Windows (cmd.exe):

scripts\integration_test.bat

The demo scenarios (app_smoke_test.dart, register_write_test.dart) need the demo fixtures, so they must run with --dart-define=OMODSCAN_DEMO_DATA=true — the script sets this for you. The seeded scenarios (device_crud_test.dart, settings_test.dart) own their state and pass with or without the flag.

Notes

  • Writes can be disabled in Settings.
  • Multiple-register writes fall back to sequential single-register writes when a device rejects function code 16 with an illegal-function exception.
  • Traffic file logging writes modbus-traffic.log in the app documents directory when enabled.

License

Released under the MIT License.

About

Mobile version of Modbus Master (Client) Utility OpenModScan

Resources

Stars

Watchers

Forks

Releases

Packages

Contributors